Arizona oversize permit rules
What Arizona charges for a single-trip OS/OW permit, the limits that trigger one, and the escort thresholds — read from the state’s own publication. This rule has been in effect since 2026-06-24; we last read the source on 2026-07-06.
$15–$40
The load has to fit inside a tier on every dimension at once — width and height and length. Exceed any one of them and it falls to the next tier up.
From $75
Priced per load rather than at a flat rate.
A load that is both oversize and overweight pays this fee only, not both.
+ $20 Permigo service fee per permit, state fees at cost.
Legal limits
Exceed any one of these in Arizona and you need a permit for this state.
| Limit | Interstate |
|---|---|
| Width | 8'6" |
| Height | 14'0" |
| Length | 65'0" |
| Gross weight | 80,000 lbs |
| Single axle | 20,000 lbs |
| Tandem axle | 34,000 lbs |
| Trailer length | 57'6" |
What the permit costs
Arizona prices a single-trip permit as by dimensional envelope. The load has to fit inside a tier on every dimension at once — width and height and length. Exceed any one of them and it falls to the next tier up.
| Band | State fee |
|---|---|
| Within 14'0" wide × 16'0" high × 120'0" long | $15 |
| Within 18'0" wide × 18'0" high | $30 |
| Anything larger | $40 |
Escort requirements
Thresholds by road class. Where two classes differ, the road you are actually on governs.
2-lane
| Width | Requirement |
|---|---|
| Over 11'0" | 1 rear escortNIGHT WINDOW (3:00 a.m. to one-half hour before sunrise, R17-6-402(D)): over 11'-14' wide = 1 rear escort; over 14'-16' = front + rear. |
| Over 14'0" | 1 front escort + 1 rear escortOver 14'-16' wide on undivided/other highways: FRONT + REAR escorts (R17-6-412 Table 4 statewide pattern, ~245 rows).ROUTE-DEPENDENT onsets: ~120 restricted segments in R17-6-412 Table 4 drop the escort onset to >12', >11', or >10' and add law-enforcement escorts (I-15 Virgin River Gorge, SR 89A Oak Creek, metro segments) — verify the routed corridor against Table 4. |
| Over 16'0" | superload permitWidth over 16' appears NOWHERE in Table 4 — case-by-case Class C authorization only (R17-6-402(E)). |
| Height | Requirement |
|---|---|
| Over 15'0" | 1 pole car · height poleNIGHT-WINDOW rule (R17-6-402(D)3): over 15' high requires a front escort with a height pole from 3:00 a.m. until one-half hour before sunrise. NO general daytime height-pole rule exists in the AAC — the Department may impose one per permit (R17-6-305 discretionary). |
| Over 16'0" | superload permitHeight over 16' exceeds the Class A ceiling — Class C Special Permit (pre-approval, avg 48h). |
| Length | Requirement |
|---|---|
| 80'0" and over | Conditions applyNo statewide length escort in AZ — but Table 4 corridors attach them: I-15 (all 29 AZ miles, Virgin River Gorge) over 100' non-articulated = F/R + 2 law-enforcement; SR 77 Mammoth–US 70 and US 60 Queen Creek canyon/tunnel 80'+ non-articulated or 110'+ articulated = F/R; SR 260 White Mountains 80'+ = F/R. SR 88 over 40' and SR 89A Prescott–Clarkdale/Sedona over 50' take Class C route approval. |
| Over 120'0" | superload permitOver 120' overall exceeds the Class A ceiling — Class C Special Permit; routing, escorts, and law-enforcement attach as permit conditions (over 120' is also ineligible for the R17-6-402 night/weekend window). |
| Front overhang | Requirement |
|---|---|
| Over 20'0" | 1 front escortFront overhang over 20': front escort (R17-6-307(C) verbatim). Overhang >4': flags by day / lights by night (307(D)). |
| Rear overhang | Requirement |
|---|---|
| Over 20'0" | 1 rear escortRear overhang over 20': rear escort (R17-6-307(C) verbatim); over 20' at BOTH ends: front and rear. |
| Weight | Requirement |
|---|---|
| Over 250,000 lbs | route survey · superloadGVW over 250,000 lb exceeds the Class A ceiling — Class C + ADOT Bridge Preservation engineering analysis (up to two weeks; certified weights; $75/$125 per 50-mile increment by preparer). Bridge-specific LE bands exist below this (I-15 Virgin River Bridge #5: 150,001-250,000 = two-LE road closures at 10 mph). |
4-lane / interstate
| Width | Requirement |
|---|---|
| Over 11'0" | 1 rear escortNIGHT WINDOW (3:00 a.m. to one-half hour before sunrise, R17-6-402(D)): over 11'-14' wide = 1 rear escort; over 14'-16' = front + rear. |
| Over 14'0" | 1 rear escortOver 14'-16' wide on interstates/divided highways: 1 REAR escort (R17-6-412 Table 4 statewide pattern, ~207 rows).ROUTE-DEPENDENT onsets: ~120 restricted segments in R17-6-412 Table 4 drop the escort onset to >12', >11', or >10' and add law-enforcement escorts (I-15 Virgin River Gorge, SR 89A Oak Creek, metro segments) — verify the routed corridor against Table 4. |
| Over 16'0" | superload permitWidth over 16' appears NOWHERE in Table 4 — case-by-case Class C authorization only (R17-6-402(E)). |
| Height | Requirement |
|---|---|
| Over 15'0" | 1 pole car · height poleNIGHT-WINDOW rule (R17-6-402(D)3): over 15' high requires a front escort with a height pole from 3:00 a.m. until one-half hour before sunrise. NO general daytime height-pole rule exists in the AAC — the Department may impose one per permit (R17-6-305 discretionary). |
| Over 16'0" | superload permitHeight over 16' exceeds the Class A ceiling — Class C Special Permit (pre-approval, avg 48h). |
| Length | Requirement |
|---|---|
| 80'0" and over | Conditions applyNo statewide length escort in AZ — but Table 4 corridors attach them: I-15 (all 29 AZ miles, Virgin River Gorge) over 100' non-articulated = F/R + 2 law-enforcement; SR 77 Mammoth–US 70 and US 60 Queen Creek canyon/tunnel 80'+ non-articulated or 110'+ articulated = F/R; SR 260 White Mountains 80'+ = F/R. SR 88 over 40' and SR 89A Prescott–Clarkdale/Sedona over 50' take Class C route approval. |
| Over 120'0" | superload permitOver 120' overall exceeds the Class A ceiling — Class C Special Permit; routing, escorts, and law-enforcement attach as permit conditions (over 120' is also ineligible for the R17-6-402 night/weekend window). |
| Front overhang | Requirement |
|---|---|
| Over 20'0" | 1 front escortFront overhang over 20': front escort (R17-6-307(C) verbatim). Overhang >4': flags by day / lights by night (307(D)). |
| Rear overhang | Requirement |
|---|---|
| Over 20'0" | 1 rear escortRear overhang over 20': rear escort (R17-6-307(C) verbatim); over 20' at BOTH ends: front and rear. |
| Weight | Requirement |
|---|---|
| Over 250,000 lbs | route survey · superloadGVW over 250,000 lb exceeds the Class A ceiling — Class C + ADOT Bridge Preservation engineering analysis (up to two weeks; certified weights; $75/$125 per 50-mile increment by preparer). Bridge-specific LE bands exist below this (I-15 Virgin River Bridge #5: 150,001-250,000 = two-LE road closures at 10 mph). |
Movement restrictions
| Restriction | In Arizona |
|---|---|
| Night travel | Night travel allowed |
| Weekends | Not specified |
| Holidays | Restricted |
Movement hours (A.A.C. R17-6-401/-402, verified 2026-07-06)
| Load | Window |
|---|---|
| ≤10′W (11′ cranes) · ≤14′6″H · ≤10′ overhangs · ≤120′L · ≤250,000 lb | CONTINUOUS 24/7 (R17-6-401(A) verbatim envelope) |
| Above the envelope | sunrise −30 min → sunset +30 min |
| Night/weekend window | R17-6-402: from 3:00 a.m. (weekend escort onset drops to >11′ wide) |
| Holidays | blackout (list per ADOT permit) |
Where these permits come from
If you file yourself, this is the office you are dealing with. Check the linked page — some states issue OS/OW permits through their highway patrol or revenue department rather than the DOT.
| Arizona permit office | |
|---|---|
| Permit office | (602) 255-0072 |
| [email protected] | |
| Permit portal | adotepro.azdot.gov |
| Information | Official page |
ADOT Permit Fees FAQ + ADOT Class A OS/OW page + ADOT Class C Permits page (all live 2026-06-24) + AZ Admin Code R17-… · azdot.gov · in effect since 2026-06-24 · source read 2026-07-06. Fees and rules change; the linked document is always the authority.